Non-Dimmable properties

Properties: LED Information

  • The virtual LED colors used when a keypad button is bound to the load. Select Top, Bottom, or Toggle LED Colors.

Advanced Properties

  • Options
  • Load #—The Load number and circuit number may be specified in the lighting plan. Adding that information here will provide the link from the lighting plan to the project and then to the reports that must be generated later (see "Creating Reports" in this document for details). If the lighting plan doesn't include load numbers, it's a good idea to create a unique load number for each load leg. To do this, assign a number for each floor (e.g., Basement = 1, Main = 2). Assign a number for each room on the floor (e.g., Kitchen=01, Master Bedroom = 02), and add a number for each light in the room (e.g., 01, 02, 03, etc.). So the load number would look something like this: '02-01-03.’ The load number must be unique for each Panelized Lighting device.
  • Watts—The wattage value of the light (or collection of lights in the load leg). You must enter this value prior to connecting the light to a module to ensure that the wattage calculations are correct and that the module does not overload.

    Example: The light leg controls six can lights in the Kitchen; each can is 100 watts. In this case, enter 600 watts (6 x 100).

  • Override Level (%)—Defines the level or on/off state that the dimmer load will be set to when the module override button is pressed or when the auxiliary override is engaged.
  • Energy Information
  • Minutes Off—The number of minutes that the load has been off since the dimmer module was last reset.
  • Minutes On—The number of minutes that the load has been on since the dimmer module was last reset.
  • Minutes On Today—The number of minutes that the load has been on today.
  • Current Power—The current power being used by the load (in watts).
  • Energy Used—The total number of watt hours used by the load since the device was last reset.
  • Energy Used Today—The total number of watt hours used by the load from 12:00 AM until 11:59 PM today.